Pacemaker Analyzers
DELTA 3000 - New Defib Analyzer /Pacer Tester
|
DELTA 3000, Defibrillator Analyzer is the latest addition of our Defibrillator Analyzer with full Pacer Tester and ECG Simulator built in.
DELTA 3000, Defibrillator Analyzer combines the complete testing functions of a Defibrillator Tester, a Pacemaker Analyzer, and a 12 Lead ECG / Arrhythmia simulator into one compact, lightweight, and easy to use instrument. No other instrument delivers the performance testing power of the DELTA 3000, Defib Analyzer / Pacer Tester.
DELTA 3000, Defibrillator Analyzer tests all defibrillators including AEDs. It measures both monophasic and bi-phasic waveforms. It tests all external pacemakers including transthoracic, transvenous, and AV sequential models. It has 12 built-in user selectable test loads for transthoracic pacing testing. The built-in ECG / Arrhythmia simulator allows performance testing of any ECG equipment.
|
|
|
 |
 |
 |
Compact, Lightweight, and Rugged |
 |
Simple, Menu Driven Operation |
 |
Large 4-line LCD |
 |
Simultaneous Display of All Test Measurements |
 |
Dedicated Print Key for Immediate Documentaion |
 |
Two year warranty when annually calibrated by Netech |
|
 |
 |
RS 232 Interface |
 |
Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time |
 |
Battery or AC Operation |
 |
Storage and Playback of output waveforms |
 |
Tests all External Pacemakers - Transthorasic, Transvenous, and AV Pacers |
 |
Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refactory Periods |
 |
50 and 60 Hz Immunity Tests |
 |
Transthorasic Test Loads: Fixed 50 Ohm or 12 User Selectable Loads to 1000 Ohms |
 |
A / V Pacer Test Load: 500 Ohm |
 |
Tests all ECG Equipment |
 |
12 lead ECG, User Selectabel Rates and Amplitudes |
 |
Performance Waveforms: Sine, Square, Triangle, and Pulse |
 |
12 Arrhythmias |
|

|
|
Defibrillator AnalyzerEnergy Measurement:Load: 50 Ohm +/- 1 % Range (High): 900 J Resolution: 1 Joule Range (Low): 0 - 100 Resolution: 0.1 Joules Accuracy: +/- 2% of the reading + 1 J for Hi Range or + 0.5 J for Low Range Maximum Voltage: 5200 V Maximum Current: 100 Amp (H) Sync. Time: 0 - 250 ms Waveform Output:Real Time: Output 1000 : 1 Stored. Discharge waveform expanded 200:1 and is repeated 8 sec. It can be viewed through the paddles and through the ECG High Level Output Pacemaker AnalyzerTranscutaneous:Test Load: 50 Ohm (Fixed) and variable 100 to 1000 Ohms user selectable Current: 1 to 200 mA Accuracy: +/- 5% + 0.5 mA Pulse Width: 0.5 to 80 ms Accuracy: +/- 1% + 0.1 ms Refractory: 20 - 500 ms Accuracy: +/- 2% or + 10 ms Atrial and Ventricular:Test Load: 500 Ohms Current: 1 to 25 mA Accuracy: +/- 5% + 0.5 mA Pulse Rate: 30 to 800 ppm. Accuracy: +/- 1% + 0.1 ms Refactory: +/- 20 - 500 ms Accuracy: +/- 2% or 10 ms Immunity Test: 50 / 60 Hz ECG ArrhythmiaSimulatorECG: Normal Sinus Rhythm.Rate: 30, 60, 90, 120, 240 Performance Waveforms:Sine, Square, Triangle and Pulse Rate: 0.5, 1, 2, 10, 15, 20, 25, 40 Hz Arrhythmias:VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR Waveform Output: 12 Lead ECG and Paddle and High Level Output Jacks. |
Power Requirements:Two 9V Alkaline Batteries Or AC Adapter  Dimension:10 x 11 x 2.25 inches (25.4 x 27.9 x 5.7 cm) Weight: 4 lbs (1.8 kg) |
|
|
 |
|

 |