Defibrillator / Transcutaneous Pacemaker Analyzer

Product Code : Defibrilator Transcutaneous Pacemaker analyzer

 The DELTA 3300 Defibrillator / Transcutaneous Pacemaker Analyzer is a precision instrument for testing defibrillators and external (Transcutaneous) Pacemakers. It combines the complete testing functions of a Defibrillator Tester, Transcutaneous Pacemaker Analyzer, and 12-Lead ECG / Arrhythmia Simulator into one compact, lightweight, and easy-to-use instrument.

The Delta 3300 tests all Defibrillators including AEDs. It measures both monophasic and Bi-Phasic waveforms.  It is compact, lightweight and easy to use. The test results can be saved in the internal memory and uploaded to the PC and printed using ProComPrint software (CD included with the unit).

Show More... Add to cart

     PRODUCT HIGHLIGHTS

    • Energy and cardioversion measurement
    • Peak voltage and current reading
    • Waveform Storage and Playback.
    • Tests all Automated defibrillators
    • Pacemaker loads from 50 to 1100 Ohm
    • Pacer Amplitude, Rate, Pulse width
    • Demand Sensitivity, Refractory period,   immunity and pulse Energy
    • 12 Lead ECG, Arrhythmia, Performance
    • Li-Ion Rechargeable Battery

     

    FEATURES

    • Large LCD Display with Backlight
    • Simple and easy to use
    • Compact & Lightweight (3lbs)
    • Test results can be saved & uploaded to PC using Netech ProComPrint software
    • Li-Ion Rechargeable Battery
    • Hard Carrying case
    • 2 Year Warranty
    • Incredible Value

     

    SPECIFICATIONS

    DEFIBRILLATOR ANALYZER

    Energy Output Measurement:

    Energy Output Measurement:

    Maximum Energy: 800 J

    Display Resolution: Based on Auto Range

    Auto Range: 2 - 9.99 J, 10-99.9 J, 100-800 J

    Resolution: 0.01 J ( 2 -9.99), 0.1 J (10-99.9), 1 J (100-500)

    Accuracy: ±1 % of reading ± 0.1 J (2-9.9), ± 1J (10-99), ± 2 % (100-500)

    Load Resistance:

    50 ohms ±1 %; non-inductive (< 1 μH)

    Sampling Time: 20 uS

    Measurement Time Window: 60 ms

    Absolute Max Peak Voltage: 5000 V

    Absolute Max Peak Current: 100 A

    Pulse Width: 60 ms

     High Level Output:

    High Range: 100:1 amplitude attenuation

    Low Range: 200:1 amplitude attenuation

    Waveform Storage / Playback:

    Discharge can be viewed via ECG outputs and paddles.

     Sync Time Measurements:

    Timing Window:

    Starts: 40 ms at each R wave peak

    Test Waveforms:

    All Waveform simulations available.

    Delay Time Accuracy: ±1 ms

    Charge Time Measurement: 30 to 60 in steps of 15 seconds.

     GENERAL INFORMATION

    Temperature Range:

    Operating: +15°C to +35°C

    Storage: 0°C to +50°C .

    Display:

    Type: LCD with LED backlight.

    Alphanumeric format: 4 X 20 characters.

    Data Input/Outputs :

    RS-232C (1) for Computer control.

    Power: 7.4 Volt Li Ion Battery.

    100-230 VAC input,  850 mA DC Charger.

     Housing: High impact ABS Plastic case.

     DIMENSIONS: D x W x H:

    10.25 x 6.25 x 2.5 Inch.

    26 X 16 x 6.4 Cm

    Weight: 1.5 kg / 3.3 lbs.

     TRANSCUTANIOUS PACEMAKER ANALYZER

    Test Load Range: 50 -1100 Ohms in steps of 100 Ohms.

    Accuracy: 50 - 500 ohm ±1 %

    500 - 1100 ohm ±1.5 %

     Pulse Measurements:

    Amplitude: 4 to 400 mA (50 ohm load)

    Accuracy: ±1 % or ± 1 mA

    Max. amplitude: 400 mA (50 Ohm Load)

    Rate: 30 to 800 ppm

    Accuracy: ±1 % or 2 ppm

    Pulse Width: 0.5 to 50 ms

    Accuracy: ±1 % or ±0.3 ms

     Demand Sensitivity Test:

    Waveforms: QRS, Square(SQR), Triangle(TRI), and Haversine (SSQ).

    Waveform width: 40, 50, 60, 70, 80, 90, 100, 200, 300, 400 ms

    Pacer Rate: 30 to 120 ppm

     ECG Output:

    Amplitude: user selectable 0.1 - 5 mV

    Resolution: 40 μV

    Pacer Input (Load dependent):

    Amplitude (50 ohm): 0 - 10 mV

    Resolution (50 ohm): 25 μV

    Amplitude: (500 ohm): 0 - 100 mV

    Resolution: (500 ohm): 1 mV

    Accuracy: ±2 %

     Immunity Test:

    Interference Signal: 50/60 Hz

    ECG signal Amplitude:0.5 to 5.0 mV

     Refractory Period Measurement:

    20 to 500 ms (both Pacing and Sensing)

    Accuracy: ±5 ms

    PATIENT SIMULATOR

    ECG General:

    Lead Configuration: 12-lead simulation.

    RL, RA, LA, LL, V1-6

    Output Impedance: RL to All leads 1000 Ohms, V Leads: 1000 ohms to RL

    High Level Output: 0.5 V/mV of low level (lead II)

    Rates: 30, 40, 50, 60, 70, 80, 90, 100, 110, 120,130, 140, 150, 160, 170, 180, 190, 200, 220, 240, 260, 280, 300 &

    310 BPM.

    Accuracy: ±1 %

    Amplitude0. 1 to 5 mV (User selectable), Lead II

    Accuracy: ± 2 % @ Lead II (SQR)

     Arrhythmia Selections:

    Ventricular Fibrillation Corse (VFBC)

    Ventricular Fibrillation Fine (VFBF)

    Ventricular Tachycardia (VTAC)

    Atrial Fibrillation (AFIB)

     

    Performance Waveforms:

    Sine, Square, Triangle:

    Rate: 0.2, 0.3, 0.4, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 Hz.

    Amplitude: 0.1, 0.25, 0.50, 1, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mV.

    Amplitude accuracy: ±2 % (Square Wave -Lead II 1.0 mV )

    Pacer Pulse:

    Pulse Width: 10mS

    Amplitude: 1.0 mV (Lead II)

    Accuracy: ± 2 %

     Order no:

    660: DELTA 3300 Defibrillator / Transcutaneous Pacemaker Analyzer

    Included all Standard Accessories.

     

     

     

Download Brochure Download Manual
Part Number Description Price
660 Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyzer Add to cart